VC003 Vapor Chamber Heatsink for Broadcom Qumran 2C
Product Description
Core Technology: Efficient Heat Conduction and Compact Structure Design
1. Innovative Zipper Fin Design
Ultra-High-Density Cooling Area: Employs 0.15mm ultra-thin aluminum sheets in an interlocking zipper arrangement, achieving an effective cooling area exceeding 2800 cm² within a 26.3mm height, improving volumetric cooling efficiency by 45%.
Optimized Aerodynamics: Fin orientation perfectly matches the standard front-to-back airflow path of data center switches, reducing airflow resistance by 25%, enabling the use of lower-power, longer-life fan systems.
Enhanced Structural Stability: Innovative interlocking connection structure ensures the high-density fin array maintains structural stability during transportation and long-term operation, with MTBF exceeding 150,000 hours.
2. Large-Area Vapor Chamber Base
Full-Coverage Heat Spreading: The 202×157mm large-area vapor chamber base fully covers the Qumran 2C chip and surrounding high-power components, eliminating local hotspots, controlling chip surface temperature delta (ΔT) to < 6°C.
High-Strength Support Design: Employs a multi-point matrix support structure, ensuring baseplate deformation remains < 0.08mm under long-term high-load operation, maintaining a stable thermal interface.
Rapid Thermal Response: Optimized working fluid ratio and capacity design quickly absorbs instantaneous power peaks during chip startup and load transients, providing excellent thermal buffering performance.
3. Nickel Plating Surface Treatment Process
Data Center Environment Adaptability: Multi-layer electroplated nickel process forms an 8-10μm dense protective layer on the substrate surface, passing 96-hour salt spray tests, perfectly adapting to the temperature and humidity variations in data center environments.
Stable Thermal Interface Performance: The treated surface flatness is < 0.05mm, with excellent chemical stability, ensuring stable thermal resistance at the chip interface over time, preventing performance degradation.
Aesthetics and Durability Combined: The nickel-plated surface not only provides excellent corrosion protection but also gives the product a professional aesthetic quality, enhancing the overall product grade.
Target Application Scenarios and Value Proposition
Key Application Scenario Analysis
1. Data Center Spine/Leaf Switch Cooling
Scenario Characteristics: Modern data center spine/leaf switches require high-density port configurations, with Qumran 2C chip power typically in the 150-250W range, and strict cooling space limitations.
VC003 Value: 26.3mm ultra-low profile design enables efficient cooling within 1U chassis, supporting 48×25G or 16×100G high-density port configurations in switches, ensuring stable operation in high-temperature environments.
2. Enterprise Core Network Switch
Scenario Characteristics: Enterprise network core equipment requires low noise and high reliability, often deployed in office environments with strict requirements for cooling solution noise control.
VC003 Value: Optimized zipper fin design reduces airflow resistance by 25%, enabling the use of low-speed quiet fans, reducing system noise by 4-6 dBA, while ensuring long-term stable equipment operation.
3. Cloud Computing & Virtualization Platform Access Switch
Scenario Characteristics: Switches in cloud computing environments need to adapt to load fluctuations caused by dynamic VM migration; cooling solutions require good transient thermal response capabilities.
VC003 Value: Vapor chamber's rapid thermal response characteristic effectively buffers instantaneous heat from load transients, preventing drastic chip temperature fluctuations, improving system stability by over 30%.
Multi-Layered Value for Customers
For R&D Teams (Technical Value)
Simplifies Thermal Design Process: Provides a comprehensively validated thermal solution, significantly shortening the thermal design verification cycle for switch products, accelerating time-to-market by 3-4 months.
Increases Design Flexibility: Compact design provides more space for PCB layout, supporting more flexible signal routing and high-density component placement.
Reduces R&D Risk: Adopts a mature and reliable thermal technology solution, avoiding product recall or field failure risks due to thermal issues.
For Product & Project Management (Business Value)
Reduces Total Cost of Ownership: High-efficiency cooling solution lowers fan power consumption, saving approximately $80-120 per device annually, with significant benefits at large-scale deployment.
Optimizes Supply Chain Management: A single component replaces a complex cooling system, reduces supplier count, simplifies procurement processes, improves supply chain stability.
Enhances Product Competitiveness: Excellent cooling performance becomes a key product selling point, supporting commitments for wider operating temperature ranges in technical specifications.
For Data Center Operators (Long-Term Value)
Improves Energy Efficiency Metrics: Reduces cooling system energy consumption, contributes to overall data center PUE optimization, supporting sustainability goals.
Ensures Service Availability: High-reliability design reduces equipment failure rates, ensures network service SLA achievement, improves customer satisfaction.
Extends Equipment Lifespan: Stable operating temperature extends chip and component service life, postpones equipment refresh cycles, protects infrastructure investment.
FAQs
Q:Do you have your own brand? A:Yes. Our brand name is GREATMINDS. |
Q:Are you a manufacture or trading company? A:We design and produce thermal products by ourselves. |
Q:Where is your plant? A:We have two plants. One is at Suzhou in eastern China, and the other is at Dongguan in southern China. |
Q:What thermal products do you supply? A:We have heatsink, fan, heapipe, vapor chamber, liquid cooling solution, and so on. |
Q:Which types of heatsinks do you supply? A:Our products cover many processes, extrusion, die casting, skived fin, zipper fin, soldering,friction stir welding, vaccum brazing, and so on. |
Q:What is the leadtime for prototype? A:It depends on different type of products. Usually it takes 2-3 weeks. |
Q:Do you have a NPI process in your company? A:Yes. Tooling samples and trial run will be strictly implemented before mass production. |
Q:What capabilities do you have in your plant? A:We have stamping, machining, and soldering production in house. |