F20053-001 DC Fan High Airflow Cooling for Telecom Equipment
Product Description
Product Core: High-Performance DC Fan Designed for Telecom Equipment
The F20053-001 is a high-performance DC fan specifically designed for telecom equipment. Featuring a ball bearing structure and a highly efficient impeller design, it provides a highly reliable cooling solution for base stations, server racks, and communication equipment with its powerful airflow and high static pressure characteristics. As a professional supplier of thermal solutions for telecom equipment, we help communication equipment manufacturers address the cooling challenges of high-power devices, ensuring stable performance during 7×24 continuous operation.
Core Values
Telecom Environment Dedicated: Optimized for 7×24 continuous operation of telecom equipment.
High Airflow Performance: Powerful airflow meets cooling requirements of high-power equipment.
High Static Pressure Characteristics: 95.57mmH₂O static pressure, easily penetrating dense heatsink fins.
Long-Life Bearings: Ball bearing design, adapting to long-term continuous operation.
Speed Monitoring: Integrated -FG/RD signal output for real-time fan status monitoring.
High Reliability: Suitable for harsh environments such as base stations and data centers.
Application Scenarios and Customer Value
Scenario 1: 5G Base Station Equipment Cooling
Scenario Requirements: 5G base station AAU, RRU and other equipment have high power consumption and are deployed outdoors or in equipment rooms, requiring high airflow fans to ensure chips operate stably in high-temperature environments.
F20053-001 Solutions:
832CFM ultra-high airflow, meeting cooling requirements of high-power equipment.
95.57mmH₂O high static pressure, penetrating dense heatsink fins.
Ball bearing design, adapting to 7×24 continuous operation.
Customer Value:
Ensures stable operation of 5G equipment in high-temperature environments.
Reduces risk of performance degradation caused by overheating.
Long-life design reduces base station maintenance frequency.
Scenario 2: Data Center Server Racks
Scenario Requirements: Server racks have densely packed equipment, high airflow path resistance, requiring high static pressure fans to ensure airflow penetrates deep into the rack.
F20053-001 Solutions:
High static pressure characteristics overcome resistance from densely packed cabling and high-density equipment.
High airflow meets cooling requirements of high-power servers.
Speed monitoring function provides real-time fan status feedback.
Customer Value:
Improved rack cooling efficiency, supporting higher deployment density.
Reduced risk of local hotspots.
Failure warning to avoid unexpected downtime.
Scenario 3: Telecom Core Equipment Rooms
Scenario Requirements: Telecom core equipment rooms operate 7×24 continuously, with extremely high requirements for fan reliability and maintainability.
F20053-001 Solutions:
Ball bearing long-life design, MTBF >70,000 hours.
-FG/RD signals for real-time fan status monitoring.
High performance meets cooling requirements of core equipment.
Customer Value:
Reduced core equipment room maintenance frequency.
Early warning of fan failures, ensuring business continuity.
Meets telecom-grade reliability requirements.
Core Customer Value Summary
| Value Dimension | Description | Target Customers |
|---|---|---|
| High Airflow Cooling | 832CFM airflow, meeting high-power equipment requirements | Base Station Equipment Manufacturers |
| High Static Pressure Penetration | 95.57mmH₂O static pressure, overcoming dense airflow resistance | Server Rack Integrators |
| Long-Life Reliability | Ball bearing design, 70,000-hour life | Telecom Core Equipment Rooms |
| Status Monitoring | -FG/RD signals, real-time fan status feedback | High-Reliability Systems |
| Telecom-Grade Design | Optimized for 7×24 continuous operation | Communication Equipment Manufacturers |
FAQs
Q:Do you have your own brand? A:Yes. Our brand name is GREATMINDS. |
Q:Are you a manufacture or trading company? A:We design and produce thermal products by ourselves. |
Q:Where is your plant? A:We have two plants. One is at Suzhou in eastern China, and the other is at Dongguan in southern China. |
Q:What thermal products do you supply? A:We have heatsink, fan, heapipe, vapor chamber, liquid cooling solution, and so on. |
Q:Which types of heatsinks do you supply? A:Our products cover many processes, extrusion, die casting, skived fin, zipper fin, soldering,friction stir welding, vaccum brazing, and so on. |
Q:What is the leadtime for prototype? A:It depends on different type of products. Usually it takes 2-3 weeks. |
Q:Do you have a NPI process in your company? A:Yes. Tooling samples and trial run will be strictly implemented before mass production. |
Q:What capabilities do you have in your plant? A:We have stamping, machining, and soldering production in house. |